Product details
Model Number: 1000KW Cummins Diesel Generator Set
Brand Name: DACPOWER BRAND
Key Specifications/Special Features:
1000KW Cummins diesel generator setDieselengineBrand: Cummins(CCEC)Model: KTA50-G3Type: Fourstrokes, directspurtingtypeCoolingway: WatercoolingWithtype: InlinetypeBore*trip: 159mm*159mmDisplacement 50 LLubricatingoilcapacity: 177 LCylinder: 16 cylindersRotatingspeed: 1500r/minor1800r/min
Theregulationofrotatingspeed: ElectronicGovernor
Startingway: DC24Vstartingwithelectricity
ACalternator
Brand: Stamford
Model: LVI634G
Type: brushless(AVRautomaticvoltageregulating)
Theconnectingwayofthephase: threephasesfourlines
Insulationdegree: Hdegree
GradingProtection: IP23
Digitalcontrolsystem
The control system use ComAp or Deepsea as controller, with active power, three-phase voltage, frequency and three-phase current, kilowatt-hour, power factor, oil pressure, coolant temperature, speed units, operating hours, battery voltage and other shows. Diesel engine over speed alarm and shutdown, low oil pressure alarm and shutdown, high temperature alarm and shutdown, over or low voltage alarm and shutdown, frequency too high or too low alarm and shutdown, And short-circuit protection.
Genset specification
Fuel consumption 0.235 L/Kw.h @ 100% Load
Length 5300mm
Width 2080mm
Height 2500mm
Weight 10000kg
Base fuel tank 8-10 hours (optional)
Soundproof enclosure 68db in 7 meters (optional)
Automatic transfer switch 1800A (optional)
Genset power 1000 Kw/1250 Kva
Genset voltage 220V-440V (Adjustable)
Theregulationofrotatingspeed: ElectronicGovernor
Startingway: DC24Vstartingwithelectricity
ACalternator
Brand: Stamford
Model: LVI634G
Type: brushless(AVRautomaticvoltageregulating)
Theconnectingwayofthephase: threephasesfourlines
Insulationdegree: Hdegree
GradingProtection: IP23
Digitalcontrolsystem
The control system use ComAp or Deepsea as controller, with active power, three-phase voltage, frequency and three-phase current, kilowatt-hour, power factor, oil pressure, coolant temperature, speed units, operating hours, battery voltage and other shows. Diesel engine over speed alarm and shutdown, low oil pressure alarm and shutdown, high temperature alarm and shutdown, over or low voltage alarm and shutdown, frequency too high or too low alarm and shutdown, And short-circuit protection.
Genset specification
Fuel consumption 0.235 L/Kw.h @ 100% Load
Length 5300mm
Width 2080mm
Height 2500mm
Weight 10000kg
Base fuel tank 8-10 hours (optional)
Soundproof enclosure 68db in 7 meters (optional)
Automatic transfer switch 1800A (optional)
Genset power 1000 Kw/1250 Kva
Genset voltage 220V-440V (Adjustable)
Shipping Information:
- FOB Port: Fuzhou
- Lead Time: 7 - 20 days
- HTS Code: 8502.12.00 00
- Dimensions per Unit: 5300 × 2080 × 2500 Centimeters
- Weight per Unit: 10000 Kilograms
- Units per Export Carton: 1
- Export Carton Dimensions L/W/H: 5300 × 2080 × 2500 Centimeters
- Export Carton Weight: 10000 Kilograms
Main Export Markets:
- Asia
- Mid East/Africa